Low-voltage switchboards with ATS

STAVR LV switchboards with ATS — backup power, distribution and protection in one assembly

STAVR provides an integrated solution that improves site safety, power supply stability and dependable backup operation under real operating conditions.

An LV switchboard with ATS may operate with several different power sources. Backfeed — for example, a generator feeding power into the utility network — can damage equipment and endanger personnel. STAVR ATS systems therefore incorporate mechanical and electrical interlocks that prevent the generator from being connected to multiple incoming supplies simultaneously.

One assemblyIncoming supply, distribution, protection and ATS in one enclosure or switchboard section.
Fewer interfacesFewer ad hoc connections between separate panels and control systems.
Retrofit applicationsCan be integrated into an existing LV distribution board, main switchboard or switchroom.
DocumentationLabelling, circuit diagrams, operating logic and maintenance access are part of the assembly.
Matched to the actual schemeThe number of incomers, power sources and bus sections is selected for the facility requirements.
Flexible logicUtility priorities, generator start, UPS or BESS coordination and maintenance modes are defined in the control sequence.
InterlocksMechanical and electrical interlocks reduce the risk of incorrect or hazardous operating conditions.
Operation and maintenanceIndication, labelling, documentation and maintenance access are designed into the assembly.
Current and voltageSelected for the load, duty and operating conditions.
Number of incomersUtility, generator, UPS, BESS or multiple sources, within the constraints of a sound engineering design.
ProtectionCircuit breakers, protection relays, SPDs and utility parameter monitoring, as required.
MonitoringDry contacts, event logging and Modbus / SCADA / BMS integration, to suit the facility requirements.
Applications

When an LV switchboard with ATS is needed

An LV switchboard with ATS integrates backup power into the overall incoming supply and distribution system. It is a typical solution for a new facility, an existing switchboard retrofit, or a switchroom upgrade to connect a generator, UPS or BESS.

STAVR treats the switchboard as a complete electrical assembly: power components, protection, transfer switch, controller, terminals, interlocks, indication, source logic, labelling and documentation must function as one system.

For a new facility

Designing from the outset allows proper provision for incomers, bus sections, backup supply, cable entries, ventilation, maintenance space and future expansion.

Retrofit applications

Where a switchboard is already in operation, backup power must be integrated into the actual site arrangement, accounting for available space, cabling and operating constraints.

Power components and controls

The transfer switch, protection, controller, relays, indication, terminals and control circuits are selected for the current, voltage, utilisation category, short-circuit conditions and load characteristics.

Controller capabilities →

Interlocks and maintenance

Critical facilities require mechanical and electrical interlocks, manual operation, clear position indication and safe maintenance access. In data centres and server rooms, an LV switchboard with ATS can form part of a multi-level redundancy system. For more on transfer requirements and maintenance modes, see ATS for data centres — power redundancy.

Typical applications

Utility / generator Conventional diesel-generator backup for a production facility, office, warehouse or critical room.
Two incomers plus backup Switchboards for facilities with two utility incomers, bus sectioning or generator / UPS backup.
Switchroom retrofit Upgrade an existing LV distribution board or main switchboard with ATS, monitoring, protection and clear labelling.
Technical parameters

The quality management system of SC ENERGY SYSTEMS-LUDGER for manufacturing STAVR ATS panels and LV switchboards with ATS is certified to DSTU EN ISO 9001:2018 (ISO 9001:2015, IDT). View the certificate and scope of certification →

Key information for initial selection

Rated current
Selected for the load, operating duty, reserve capacity and service conditions.
Voltage
230 / 400 V; other configurations to project specification.
Number of incomers
Utility/generator, two utility incomers, generators, UPS or BESS, depending on the power scheme.
Number of poles
2P / 3P / 4P, depending on the earthing system, neutral arrangement and site requirements.
Protection
Circuit breakers, fuses, protection relays, SPDs and utility parameter monitoring, as required.
Enclosure
Metal enclosure or switchboard sections; IP rating, ventilation, cable entries and installation clearances are selected for the installation conditions.
Supervisory monitoring
Dry contacts, event logging and Modbus / SCADA / BMS integration, to suit the facility requirements.